Generators & Mine Site Diesel Generators Online Auction
AUCTION ITEMS INCLUDE
- ATLAS COPCO QAS125 DIESEL GENERATOR
- 3 x ATLAS COPCO QAS80 DIESEL GENERATORS
- 2 x ATLAS COPCO QAS150 DIESEL GENERATORS
- ATLAS COPCO QAS200 DIESEL GENERATOR
- 5 x CUMMINS GENERATOR, 170KVA
- 2012 CUMMINS GENERATOR, MODEL# C150 D2R, 150KVA
- SE POWER GENERATOR, 200KVA
- WEST POWER GROUP GENERATOR, 200KVA
- UON C110D5, 110KVA
- UON C160D, 160KVA
- UON 200KVA DIESEL GENERATOR
- 2 x FG WILSON P88-2 GENERATOR, 88KVA
- 2 x FG WILSON P55-2 DIESEL GENERATOR, 55KVA
- FG WILSON P165-2 DIESEL GENERATOR, 165KVA
Inspection available on Monday the 7th of October from 9:00am to 3:00pm, and Monday the 14th of October from 9:00am to 3:00pm.
Condition of Site Entry
Enclosed Footwear MUST be worn onsite.
All items are sold ‘as is, where is’
All items at Ross’s Auctions are sold on an ‘as is, where is’ basis. This means the item is being sold in its current condition, regardless of any faults or damage. The bidder accepts full responsibility in satisfying themselves with the item prior to bidding. It is recommended that that if the bidder is in doubt, not to bid as no returns or refunds will be made.
PICK UP: Goods to be collected from Tuesday the 15th to Friday the 18th of October, from 8:30am to 4:00pm from Ross's Auctioneers & Valuers, 453 Orrong Rd, Welshpool, WA. (All goods must be removed by 4:00pm on Friday the 18th of October).
NOTE: To collect your goods, please ensure you have a valid form of Photo Identification present (such as a Driver's Licence) if you are requested to confirm your identity.
NOTE: Please adhere to the specified Collection Period to avoid any delays. All uncollected goods beyond the designated timeframe will be considered abandoned by the Buyer and subject to resale to recover Storage Fees. In the event of a late collection, a Late Collection Fee of $20 per item, per day, will apply starting AFTER the designated timeframe. Payment of all accrued fees of late-collected goods will be required for goods to be released.
ATLAS COPCO QAS125 DIESEL GENERATOR, 6 CYL CUMMINS DIESEL, PARTNER ALTERNATOR, ASSET# GE6089, HOURS NOT SIGHTED, NO FUEL CAP, UNREADABLE OUT OF SERVICE TAGS
Bidding Closed
ATLAS COPCO QAS80 DIESEL GENERATOR 6 CYL CUMMINGS 6BT5.9-G2 ENGINE, PARTNER ALTENATOR ASSET# GE6098, NO FUEL CAP
Bidding Closed
ATLAS COPCO QAS80 DIESEL GENERATOR 6 CYL CUMMINS 6BT5.9-G2 ENGINE, PARTNER ALTERNATOR ASSET# GE6097, SOLAR PANEL, UNREADABLE OUT OF SERVICE TAGS, HRS NOT SIGHTED
Bidding Closed
ATLAS COPCO QAS150 DIESEL GENERATOR 6 CYL CUMMINGS ENGINE, PARTNER ALTERNATOR, ASSET# GE0109, SOLAR PANEL, 16531 HRS SHOWING
Bidding Closed
ATLAS COPCO QAS150 DIESEL GENERATOR, NO ENGINE, PARTNER ALTERNATOR 12,929 HRS SHOWING, ASSET# GE6050
Bidding Closed
ATLAS COPCO QAS200 DIESEL GENERATOR, 6 CYL CUMMINGS ENGINE, 24,262 HRS SHOWING, ASSET# GE6110
Bidding Closed
ATLAS COPCO GENERATOR, MODEL# QAS 150, SERIAL# YA3-027050-DW612173-WUX612173, DOM: 2013, 150 KVA, 120 KW, 400 VOLTS, SKID MOUNTED POWERED BY LEVOY SOMER, 6 CYLINDER DIESEL ENGINE, 2 x OUT OF SERVICE TAGS ON BATTERY ISOLATOR (UNABLE TO READ), FUEL CAP MISSING, EMERGENCY STOP BUTTON MISSING, 12,923 HOURS SHOWING, ASSET# GE6049, PARTNER ALTERNATOR
Bidding Closed
CUMMINS GENERATOR, M/N#C170D5, S/N#L14I701573, DOM:2014, 170 KVA (STANDBY), 155 KVA (PRIME), 416 VOLTS, 1,216 HOURS SHOWING, TYNE POCKETS, BATTERY ISOLATOR SWITCH, GENERATOR DISTRIBUTION BOARD, 172 - GEN 165
Bidding Closed
CUMMINS GENERATOR, M/N#C170D5, S/N#L14I701574, DOM:2014, 170 KVA (STANDBY), 155 KVA (PRIME), 416 VOLTS, 9,906 HOURS SHOWING, TYNE POCKETS, BATTERY ISOLATOR SWITCH, GENERATOR DISTRIBUTION BOARD, FIRE EXTINGUISHER, 172 - GEN 135
Bidding Closed
CUMMINS GENERATOR, M/N#C170D5, S/N#L14I701576, DOM:2014, 170 KVA (STANDBY), 155 KVA (PRIME), 416 VOLTS, HOURS NOT SIGHTED, TYNE POCKETS, BATTERY ISOLATOR SWITCH, GENERATOR DISTRIBUTION BOARD, SURFACE RUST/RUST EVIDENCE, BATTERY REMOVED, 172 - GEN - 167
Bidding Closed
CUMMINS GENERATOR, M/N#C170D5, S/N#L14I701607, DOM:2014, 170KVA (STANDBY), 155KVA (PRIME), 416 VOLTS, HOURS NOT SIGHTED, TYNE POCKETS, BATTERY ISOLATOR SWITCH, GENERATOR DISTRIBUTION BOARD, BATTERY REMOVED, PARTS LOOSE IN UNIT, 72 - GEN 113
Bidding Closed
2012 CUMMINS GENERATOR, MODEL# C150 D2R, S/N# A12K297158, 150 KVA, SKID MOUNTED, HOURS NOT SIGHTED, BATTERY REMOVED, REPORTED AS HAVING 7,679 HOURS, ASSET# GNCC067, PARTS LOOSE IN UNIT, TAG STATIONS PLUG BROKEN EXPOSING, LIFE GUARD 34 ON END OF GENERATOR (B1404554)
Bidding Closed
2011 SE POWER GENERATOR, M/N# DPS 200, S/N# 303201, 200 KVA, SKID MOUNTED, HOURS NOT SIGHTED, BATTERY REMOVED, REPORTED AS HAVING 17, 370 HOURS, ASSET# GNC130, (B1404554)
Bidding Closed
CUMMINS DIESEL GENERATOR SET, MODEL#C66D5, SERIAL#L14I207512, 60 KVA, 416 VOLTS, 4 CYLINDER CUMMINS ENGINE, HOURS NOT SIGHTED, DAMAGE TO END RAIL, #172-GEN 145, YOM: 2014
Bidding Closed
WEST POWER GROUP GENERATOR, MODEL# CU221TSX, SERIAL# 10112-002, 200 KVA, 415 VOLTS, DOM: 2016, ASSET# GE7049, POWERED BY CUMMINS ENGINE, MODEL# QSB7-G5 NR3, HRS NOT SIGHTED, EMERGENCY STOP DAMAGED
Bidding Closed
WEST POWER GROUP GENERATOR, MODEL# CU221TSX, SERIAL# 10176-003, DOM: 2016, 415 VOLTS, 200 KVA, 160 KW, REPORTED AS "DECONTACTOR REMOVED", 6 CYLINDER DIESEL CUMMINS ENGINE, HOURS NOT SIGHTED, CONTROL PANEL DOOR LOCKED, NO KEYS, 415 VOLT, WIRING CUT, ASSET# GE7062
Bidding Closed
2012 UON C110D5, 110 KVA, GENERATOR, 6 CYL CUMMINGS DIESEL, 415V, S/N# H12I400771, 160 KVA ASSET# G56031, HRS NOT SIGHTED, PANEL LOCKED
Bidding Closed
UON C160D 160 KVA, GENERATOR, 6 CYL CUMMINGS DIESEL, 415V, S/N# A14G299319, ASSET# GE6082, HRS NOT SIGHTED, CONTROL PANEL REMOVED, LOOSE IN UNIT END PANEL REMOVED
Bidding Closed
2014 UON 200 KVA, DIESEL GENERATOR MODEL# C200D5EKC-1 6 CYL CUMMINGS ENGINE, S/N# H13K556939, ASSET# GE5035, UNIT IS DENTED
Bidding Closed
2012 FG WILSON GENERATOR, M/N# P88-1, S/N# FGWPEP39KJSC00195, 88 KVA, SKID MOUNTED, HOURS NOT SIGHTED, BATTERY REMOVED, REPORTED AS HAVING 23,766 HOURS, ASSET# GN445, PARTS REMOVED AS PER OUT OF SERVICE TAGS, CONTROL PANEL REMOVED, (B1404554)
Bidding Closed
FG WILSON P88-1, 88KVA DIESEL GENERATOR, 4 CYL PERKINGS (NOTE: RADIATOR AND FAN REMOVED - MISSING), HOURS SHOWING: 27492 HRS, ASSET#GNC228, BATTERY REMOVED (B3486128)
Bidding Closed
FG WILSON P55-2, 55KVA DIESEL GENERATOR, 4 CYL PERKINGS (NOTE: CONTROL PANEL REMOVED), HOURS REPORTED AS: 27492 HRS, ASSET#GNC281 (B3486128)
Bidding Closed
FG WILSON P55-2, 55KVA, GENERATOR SET, DEISEL 4 CYL PERKINS, HOURS: UNKNOWN, PIN# FGWPEP29VJMU00355, NOTE (COOLER & RADIATOR REMOVED/MISSING) ASSET# LPS4, # U8887, 1 x SMALL SOLAR PANELS, VARIOUS PARTS REMOVED
Bidding Closed
PR POWER DIESEL GENERATOR SET, MODEL#GMS42CS - AU, SERIAL#PL6781/16, 43 KVA, 415/240V, 3 PHASE, 1500 RPM, 4 CYLINDER CUMMINS ENGINE, CONTROL PANEL MISSING, ENGINE HOURS NOT SIGHTED, TAGGED OUT SERVICE WITH LOCK, UNKNOWN WORKING CONDITION, #G1131, 2 x SMALL SOLAR PANELS
Bidding Closed
PR POWER GENERATOR, M/N#GM530CS - AU, S/N#PL6489/23, DOM:2014, 33 KVA (STANDBY), 30 KVA (PRIME), 415 VOLTS, HOURS NOT SIGHTED, TYNE POCKETS, 1 x SOLAR PANEL, CONTROL PANEL DOOR DAMAGED, SURFACE RUST/RUST EVIDENCE
Bidding Closed
WEST POWER GROUP GENERATOR, MODEL# CU221TSX, SERIAL# 10153-002, 200 KVA, 415 VOLTS, ASSET# GE6168, DOM: 2016, POWERED BY CUMMINS ENGINE, MODEL# QSB7-G5 NR3, HRS NOT SIGHTED, OUT OF SERIVCE TAGS, APPLIED TO ISOLATOR - NOT READABLE
Bidding Closed
FG WILSON P165-2, 165KVA DIESEL GENERATOR, 6 CYL PERKINGS, HOURS REPORTED AS SHOWING: 18784 HRS, ASSET#GNC181, BATTERY REMOVED (B3486128)
Bidding Closed
PR POWER GENERATOR, M/N#WPS150BS-AU, S/N#PL8024/8, DOM:2018, 165 KVA (STANDBY), 150 KVA (PRIME), 415 VOLTS, RUN HOURS SHOWING: 24401, TYNE POCKETS, 1 x END PANEL REMOVED, SURFACE/RUST EVIDENCE
Bidding Closed
PR POWER GENERATOR, M/N#WPS150BS-AU, S/N#PL7818/12, DOM:2017, 165 KVA (STANDBY), 150 KVA (PRIME), 415 VOLTS, HOURS NOT SIGHTED, TYNE POCKETS, BATTERY ISOLATOR SWITCH, 1 x SIDE PANEL MISSING, BATTERY REMOVED, SURFACE RUST/RUST EVIDENCE
Bidding Closed
FG WILSON P110-2, 110KVA DIESEL HOURS SHOWING: 23685 HRS, ASSET# GNCC013, 4 CYL PERKIINS ENGINE, BATTERY REMOVED, HOURS NOT SIGHTED, REPORTED AS ALTERNATOR END COVER MISSING, WIRING EXPOSED (B3486128)
Bidding Closed
Generators & Mine Site Diesel Generators Online Auction
AUCTION ITEMS INCLUDE
- ATLAS COPCO QAS125 DIESEL GENERATOR
- 3 x ATLAS COPCO QAS80 DIESEL GENERATORS
- 2 x ATLAS COPCO QAS150 DIESEL GENERATORS
- ATLAS COPCO QAS200 DIESEL GENERATOR
- 5 x CUMMINS GENERATOR, 170KVA
- 2012 CUMMINS GENERATOR, MODEL# C150 D2R, 150KVA
- SE POWER GENERATOR, 200KVA
- WEST POWER GROUP GENERATOR, 200KVA
- UON C110D5, 110KVA
- UON C160D, 160KVA
- UON 200KVA DIESEL GENERATOR
- 2 x FG WILSON P88-2 GENERATOR, 88KVA
- 2 x FG WILSON P55-2 DIESEL GENERATOR, 55KVA
- FG WILSON P165-2 DIESEL GENERATOR, 165KVA
Inspection available on Monday the 7th of October from 9:00am to 3:00pm, and Monday the 14th of October from 9:00am to 3:00pm.
Condition of Site Entry
Enclosed Footwear MUST be worn onsite.
All items are sold ‘as is, where is’
All items at Ross’s Auctions are sold on an ‘as is, where is’ basis. This means the item is being sold in its current condition, regardless of any faults or damage. The bidder accepts full responsibility in satisfying themselves with the item prior to bidding. It is recommended that that if the bidder is in doubt, not to bid as no returns or refunds will be made.
PICK UP: Goods to be collected from Tuesday the 15th to Friday the 18th of October, from 8:30am to 4:00pm from Ross's Auctioneers & Valuers, 453 Orrong Rd, Welshpool, WA. (All goods must be removed by 4:00pm on Friday the 18th of October).
NOTE: To collect your goods, please ensure you have a valid form of Photo Identification present (such as a Driver's Licence) if you are requested to confirm your identity.
NOTE: Please adhere to the specified Collection Period to avoid any delays. All uncollected goods beyond the designated timeframe will be considered abandoned by the Buyer and subject to resale to recover Storage Fees. In the event of a late collection, a Late Collection Fee of $20 per item, per day, will apply starting AFTER the designated timeframe. Payment of all accrued fees of late-collected goods will be required for goods to be released.